TM 10-4930-247-13&P
4-15.
RECIRCULATION NOZZLE ASSEMBLY REPAIR -cont.
(18)
Install preformed packing (1) in dust cap (2).
(19)
Install dust cap (2) over end of inlet adapter (8).
(20)
Connect recirculation nozzle assembly to CCR nozzle in fuel system (para 2-12d).
(21)
Start up fuel system (para 2-12g) and check recirculation nozzle assembly for leaks.
4-21
|