TM 10-4930-245-13&P
4-10. CCR NOZZLE ASSEMBLY REPAIR - continued.
b.
Repair - continued.
WARNING
Drycleaning solvent, AA 711 Types I and II, used to clean parts is potentially
dangerous to personnel and property. Use in a well-ventilated area as the
fumes are dangerous if inhaled. Avoid repeated and prolonged skin
contact. Do not use near open flame or excessive heat. Flash point of
solvent is 138°F. on the discharge end of the nozzle.
b.
Repair.
(1)
Clean parts with drycleaning solvent. Dry with clean wiping rag.
(2)
Inspect all parts for damage. Look for damage threads, worn, scored, or deformed parts, cracks or
corrosion.
(3)
Replace any damaged parts found by inspection.
c.
Assembly.
(1)
Install gasket (12) in coupling half(13).
(2)
Install plug (11) in coupling half (13) and lock in place.
(3)
Coat threads of coupling half (13) with anti-seize compound. Wipe off any excess with clean, dry
wiping rag.
(4)
Clamp strainer body (6) in a soft face vise and screw coupling half (13) into strainer body (6). Remove
from vise.
(5)
Install strainer (8) into strainer housing (7).
(6)
Coat preformed packing (9) with silicone compound and install into groove at end of strainer housing
(7) over strainer (8) lip.
(7) Install strainer body (6) into strainer housing (7) and hand tighten.
NOTE
The two grounding cable lugs should be closest to the housing.
(8)
Attach the two lugs on ground assembly cable (4) and lug on cap assembly cable (2) to the housing (5)
with screw (3).
(9)
Pull dust cap (2) on collar (1).
4-10
|