TM 10-4930-245-13&P
Table 2-1. Operator Preventive Maintenance Checks and Services - continued.
Item
No.
Interval
Location
Item to be
Inspected
Procedure
Not Fully Mission
Capable If:
CLOSE-CIRCUIT
REFUELING
NOZZLE
7
During
Nozzle Housing
Inspection for leaks.
Any leak found.
8
During
Handle
Inspect handle action to see that it
Fails to operate
operates smoothly.
smoothly.
9
After
Locking lugs and
Inspect for missing or damaged lugs.
Lugs missing or
stayback lugs
There should be three stayback lugs and
damaged.
nine locking lugs.
10
After
Nozzle Housing
Inspection for leaks.
Any leak found.
11
After
Cable Assembly
Inspect cable for loose connection, frayed
Damaged or frayed
or damaged cables, bent or damaged plug
cables. Bent or
or clip.
damaged plug or clip.
12
After
Cap Assembly
Inspect cap assembly cap for cracks,
Cap cracked or cable
burrs or damage. Inspect cable for
broken.
breaks, frays and security.
13
After
Coupling
Inspect coupling for leaks.
Any leak found.
Assembly
2-8
|