TM 10-4930-243-13&P
5-3. GFA ASSEMBLY REPAIR - continued.
a.
Disassembly - continued.
WARNING
Dry cleaning solvent, AA-711-Types I and II used to clean parts is potentially dangerous to personnel and
property. Use in a well-ventilated area as the fumes are dangerous if inhaled. Avoid repeated and
prolonged skin contact. Do not use near open flame or excessive heat. Flash point of solvent is 138F.
b.
Repair.
(1)
Clean all parts in dry cleaning solvent
(2)
Inspect all parts for damage. Look for damaged threads, broken, worn, scored, or deformed parts, cracks
or corrosion.
(3)
Replace any damaged parts found during inspection.
c.
Assembly.
(1)
Position actuator lever (28) on body (29) and secure with lever pin (27) and retaining ring (26).
(2)
Align the three holes in the right operating lever (24) and left operating lever (25) with the three holes in
actuator lever (28).
(3)
Install three screws (23), six flat washers (22) and three lock nuts (21), tighten hand tight only.
(4)
Install the valve actuating handle (20) between the two operating levers (24) and (25) and install four lock
washers (19) and four screws (18).
(5)
Tighten the three nuts (21) and three screws (23) installed in Step (3).
5-22
|