TM 10-4930-243-13&P 5-2.  CCR NOZZLE ASSEMBLY REPAIR - continued. c. Assembly - continued. (28) Using a soft jaw chuck or vise, assemble actuating cam (14) on the right handle side plate (12) with screws (13) torque to 150 in-lb.  Repeat for remaining side plate (12). NOTE Actuating cam must be behind diaphragm retainer . (29) Place nozzle assembly into soft faced vise and position one washer (10) on housing (17) and insert the left side actuating cam (14) into the curved slot on housing (17) with the handle side plate (12) in the OPEN (up) position. (30) Insert bushing (11) into handle side plate (12); place second washer (10) on outside of handle side plate and secure to housing (17) with screw (9).  Tighten screw (9) to 135 - 150 in-lb torque. (31) Insert spring (16) and valve latch actuator (15) into housing (17) latch cavity (right side).  Attach the right side  handle  side  plate  and  parts  as  described  in  steps  30  and  31  while  holding  the  valve  latch  actuator (15). (32) Mount the handle (8) between the two handle side plates (12) and secure with four screws (7).  Tighten four screws (7) to 50±5 in-lbs torque. (33) Install  valve  actuating  ring  (18)  into  housing  (17)  by  screwing  it  onto  the  diaphragm  assembly  (21)  until .105 - .135 inch of diaphragm assembly (21) shows past the valve actuating ring (18).  Use dial caliper to verify  the  .105  -  .135  inch  requirement.    Holes  in  valve  actuating  ring  should  be  in  the  OPEN/CLOSED position. (34) Install regulator spring (6) and spring retainer (5) into housing (17) over flow indicator. NOTE Position lockpin at the top or bottom of housing. (35) Carefully install lockpin (4) on end plate (2) using a soft jaw chuck or vise with screw (3). (36) Position end plate (2) on housing (17).  Ensure  lockpin  (4)  is  in  valve  actuating  ring  (18)  and  the  spring retainer (5) is positioned in the center hold. WARNING End cover is under spring pressure.  Keep pressure on end cover while installing screws. (37) Secure end plate (2) to housing (17) with four screws (1). (38) Place handle (8) in the CLOSED position and pull collar (28) to remove piston compression tool. NOTE If strainer components and ground cables were removed, assemble (ref. 4-10). 5-16

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business