TM 10-4930-243-13&P
5-2. CCR NOZZLE ASSEMBLY REPAIR - continued.
c.
Assembly - continued
(15)
Place housing (17), with discharge end facing up, into a soft face vise and tighten only enough to prevent
housing from turning or falling from vise.
(16)
Align body wrench with nine locking lugs and press down until the collar (28) trips in the forward position.
CAUTION
To reduce the friction between the locking lugs and the collar, slightly pull back on the collar
NOTE
Always align the slot in the collar and the tab on the housing
(17)
Tighten the assembly to 300 in-lb.
(18)
Pull back on collar (28) to release the body wrench, remove body wrench. Remove nozzle assembly from
vise.
5-12
|