TM 10-4930-243-13&P
5-2. CCR NOZZLE ASSEMBLY REPAIR - continued.
a.
Disassembly - continued.
(24)
While holding collar spring (29) and collar (28) together, remove collar (28) and collar spring (29) from
housing (17).
(25)
Carefully place collar (28), with body wrench still attached, on a workbench with discharge end down.
(26)
Remove collar spring (29).
(27)
Remove collar (28).
(28)
Remove spring retainer (30) and stay back spring (31) from collar (28)
(29)
Remove lug retaining ring (32), nine locking lugs (33), three stay back detents (34) and lug wire (35) from
body (27).
(30)
Remove two wiper seals (36) from body (27). Discard wiper seals.
(31)
Remove packing (37) from housing (17). Discard packing.
(32)
Unscrew strainer housing (38) from housing (17).
5-6
|