TM 10-4930-243-13&P
2-8. EXPLANATION OF TABLE.
Table 2-1 contains a tabulated listing of preventive maintenance checks and services which must be performed by the
operator.
Table 2-1. Operator's Preventive Maintenance Checks and Services
NOTE: Within designated interval, these checks are to be performed in the order listed.
B - Before
D - During
A - After
LOCATION
ITEM
INTERVAL
ITEM TO BE
PROCEDURE
NOT FULLY MISSION
NO.
INSPECTED
CAPABLE IF:
CL0SED-CIRCUIT
REFUELING
NOZZLE
1
Before
Locking Lugs and
Remove dust cover. Inspect for missing or
Lugs missing or damaged.
Stay back Lugs
damaged lugs. There should be three stay
back lugs and nine locking lugs.
2
Before
Nozzle Housing
Inspect for leaks.
Any leak found
3
Before
Handle
Inspect handle action to see that it operates
Fails to operate smoothly.
smoothly.
4
Before
Cable Assembly
Inspect cable for loose connection, frayed or
Damaged or frayed cables.
damaged cables' bent or damaged plug or
Bent or damaged plug or
clip.
clip.
5
Before
Cap Assembly
Inspect cap assembly cap for cracks, burrs or
damage. Inspect cable for breaks, frays and
security.
6
Before
Coupling Assembly
Inspect coupling for leaks.
Any leak found.
7
During
Nozzle Housing
Inspect for leaks.
Any leak found.
8
During
Handle
Inspect handle action to see that it operates
Fails to operate
smoothly and fuel flows when in the open
smoothly or fuel does
position.
not flow in open position.
ADAPTER,
GRAVITY
ASSEMBLY
9
During
Gravity Fill
Inspect Adapter for leaks.
Any leak found
Adapter
2-6
|