TM 10-4930-242-13&P
5-2.
D-1 FUELING NOZZLE REPAIR - continued.
NOTE
If bearing is difficult to remove, recommend outlet end of nozzle collar
be soaked in light motor oil to assist in removal. (Do not engage nozzle
onto an adapter, this will create a load on bearing.)
(7)
Push one end of collar bearing (13) to cause the other end to protrude from collar bearing slot on nozzle
collar (14). Using pliers, pull the collar bearing out of groove and discard.
5-4
|