TM 10-4930-241-13
4-13. DISCHARGE AND SUCTION HOSE REPAIR (TYPICAL) - cont
CAUTIONS
* To prevent premature failure of hose assembly, gaskets certified for arctic service must be installed. If
a new dust cap or female coupling has been installed, remove and discard black gaskets supplied with
the new components and replace them with arctic service gaskets.
* Ensure gasket is fully seated in gasket seat of coupling/dust cap to prevent leaks in assembled
components.
(14)
Install gasket (5, figure 4-2) in female coupling (6).
(15)
Install gasket (11) in dust cap (10).
(16)
Connect split ring (9), chain (8) and split ring (7) to dust cap (10) and male coupling (12).
(17)
Connect split ring (1), chain (2) and split ring (3) to dust plug (4) and install in female coupling (6).
(18)
Install dust plug (4) in female coupling (6).
4-13
|