TM 10-4930-241-13
2-21. PREPARATION FOR MOVEMENT - CONT.
m.
Fuel System - Fuel Tank Discharge to Secondary 600 GPM Pump Input Removal. Refer to figure 2-54.
WARNING
Do not touch surfaces with bare skin. Bare skin will freeze to metal surfaces in
subzero temperatures. Always wear arctic mittens when handling components.
CAUTION
To prevent contamination of fuel system components use care when
disconnecting coupling to avoid getting ice, snow, dirt, sand and debris on
coupling mating surfaces or in hoses.
NOTE
Refer to para 2-16e for disconnect of quick disconnect couplings.
(1)
Disconnect end of noncollapsible hose (20) from input of secondary 600 GPM pump (21)
(2)
Disconnect 10 foot noncollapsible hose (20) from valve side of fueling manifold (19).
(3)
Disconnect fueling manifold (19) from other end of noncollapsible hoses (18).
(4)
Disconnect one end of noncollapsible hoses ( 18) from fueling manifold (11).
(5)
Disconnect two 10 foot noncollapsible hoses ( 18).
(6)
Disconnect valve section (17) from reducer (16).
(7)
Disconnect female reducer (16) from fueling manifold (13).
(8)
Disconnect fueling manifold (13) from discharge hose i 14) on tank (15).
(9)
Disconnect fueling manifold (13) from noncollapsible hoses (12).
(10)
Disconnect three 10 noncollapsible hoses (12) and disconnect from fueling manifold (11).
(11)
Disconnect fueling manifold (ii ) from one end of noncollapsible hoses (10).
(12)
Disconnect one end of noncollapsible hoses (10) from fueling manifold (7) with two valves
and disconnect three noncollapsible hoses (10).
(13)
Disconnect fueling manifold 17) with two valves from discharge hose (8) on fuel tank (9).
(14)
Disconnect fueling manifold (7) with two valves from end of noncollapsible hoses (6).
(15)
Disconnect noncollapsible hoses (6) from fueling manifold (3) with two valves and
disconnect seven noncollapsible hoses (6).
(16)
Disconnect fueling manifold (3) with two valves from discharge hose (4) on fuel tank (5).
2-109
|