TM 10-4930-240-13
2-20. PREPARATION FOR MOVEMENT-cont.
f.
Remove Air Ducts. Refer to figure 2-26.
(1)
Loosen clamp (12).
(2)
Slide end of air duct (11) off defrost shroud of filter separator (13).
(3)
Remove clamp (12) from air duct (11).
(4)
Loosen clamps (8 and 10).
(5)
Slide ends of air ducts (7 and 11) off of coupler (9).
(6)
Remove clamp (10) from air duct (11).
(7)
Remove clamp (8) from air duct (7).
(8)
Loosen clamps (4 and 6).
(9)
Slide ends of air ducts (3 and 7) off of coupler (5).
(10) Remove clamp (6) from air duct (7).
(11) Remove clamp (4) from air duct (3).
(12) Loosen clamp (2) and slide air duct (3) off of deflector (1).
(13) Remove clamp (2) from air duct (3).
g.
Remove Deflector. Refer to figure 2-27.
(1) Remove four pins (11) and lift upper frame (9) and attached deflector (10) from lower frame (2).
(2) Remove pins (7) from mount (6) on 200 GPM pump.
(3) Remove pins (5) and brace (4) Repeat for other brace (8).
(4) Repeat steps (2) and (3) for other brace (8).
(5) Lower locator arms (1) on lower frame (2) to unlock position.
(6) Remove lower frame (2) from exhaust extension (3) on 200 GPM pump.
(7) Stow deflector components in storage box as shown on loading plan.
2-65
|