TM 10-4930-240-13
2-17. OPERATING PROCEDURES - cont.
(14) Open 3-inch manifold (9).
(15) Close valve section (10).
(16) Close valve section (11).
(17) Connect D1 nozzle (15) to aircraft refueling adapter. Refer to TM 10-4930-242-13&P.
WARNING
To prevent injury to personnel and damage to the equipment, use extreme care
when defueling. Fuel capacity of 500 gallon drums must not be exceeded. Drums
could leak or rupture if over-pressurized.
(18) For operation of the 200 GPM pump (12), refer to TM 10-4320-342-10.
(19) When aircraft is defueled, shut down 200 GPM pump. Refer to TM 10-4320-342-10.
(20) Disconnect D1 nozzle (15) from aircraft adapter. Refer to TM 10-4930-242-13&P.
h. Fuel System Shutdown.
(1) Shut down filter separator (14) Refer to TM 10-4330-236-13.
(2) Shut down 200 GPM pump (12). Refer to TM 10-4320-342-10.
2-18. DECALS AND INSTRUCTION PLATES.
For location and description of data plates used on the AFARE system, refer to figure 2-21.
Refer to the applicable technical manual for decals and instruction plates on the following equipment:
200 GPM Pump Assembly................................................................ TM 10-4320-342-10
Closed Circuit Refueling (CCR) Nozzle and Gravity Fill Adapter....... TM 10-4930-243-13&P
Single Point Refueling Nozzle(D-1 Type).......................................... TM 10-4930-242-13&P
500 Gallon Collapsible Drum ............................................................ TM 10-8110-203-12&P
200 GPM Fuel Filter Separator ......................................................... TM 10-4330-236-13
2-55
|