TM 10-4930-240-13
2-17. OPERATING PROCEDURES - cont.
Refuel Mode. Refer to figure 2-20.
NOTE
Couplers may be opened to allow fuel flow from one, two or three fuel drums.
Open couplers as needed to support your mission requirements.
(1) Set couplers (1, 2, and 3) to open.
(2) Open both gate valves (4 and 5) on fueling manifold assembly (6).
(3) Close gate valve (7) on pressure reducing assembly (8).
(4) Close 3-inch manifold (9).
(5) Open valve section (10).
(6) Open valve section (11).
(7) For operation of 200 GPM pump (12), refer to TM 10-4320-342-10.
(8) For operation of filter separator, refer to TM 10-4330-236-13.
(9) Connect fuel nozzle (15) to aircraft refueling adapter. Refer to TM 10-4930-243-13&P to connect
CCR nozzle or gravity fill adapter. Refer to TM 10-4930-242-13&P to connect D1 nozzle.
(10) When aircraft fuel tank is full, disconnect fuel nozzle (15) from aircraft adapter. Refer to TM 10-
4930-243-13&P to disconnect CCR nozzle or gravity fill adapter. Refer to TM 10-4930-242-13&P
to disconnect D1 nozzle.
Defuel Mode. Refer to figure 2-20.
NOTE
Couplers may be opened to allow fuel to fill one, two or three fuel drums. Open
couplers as needed to support your mission requirements.
(11) Set couplers (1, 2 and 3) to open.
(12) Open gate valve (4) and close gate valve (5) on fueling manifold assembly (6).
(13) Open gate valve (7) on pressure reducing assembly (8).
2-53
|