TM 10-4930-240-13 Table 2-1.  Operator Preventive Maintenance Checks and Services for Model AFARE100 - cont. Location Item Interval Procedure Not Fully Mission No. Item to Capable If: Check/Service 9 Before Air Ducts Inspect ducts for tears and damaged Ducts torn, clamps or missing clamps damaged or missing. 10 Before Deflector a.  Inspect deflector for secure Deflector loose Assembly connection to 200 gpm pump. b.  Inspect for loose, damaged or Hardware damaged or missing attaching hardware. missing. c.  Inspect deflector for bent, cracked Deflector not serviceable. or damaged frame 2-24