TM10-4930-239-12&P
b. Clean.
(1) Remove all build up of dirt, oil, and debris from all mating surfaces and clamping areas.
WARNING
DO NOT breath dry cleaning solvent vapors for long periods of time or allow
solvent to come into contact with skin for an extended time. DO NOT use solvent
near open flames or excessive heat.
(2) Clean all metallic parts with a clean soft cloth (Appendix E, Item 1) or a medium bristle brush (Appendix E, Item
2), and cleaning solvent (Appendix E, Item 3).
(3) Allow parts to dry.
c. Inspection.
(1) Inspect all metal parts for cracks, cor rosion, or broken fittings.
(2) Examine all coupling half gaskets for cracks, tears, or nicks.
d. Assembly.
(1) Install split ring (40) onto coupling half (12).
(2) Install wye (18), new gasket (39), eight nuts (38), eight new lock washers (37), eight flat washers (36), and
eight screws (35) onto tee (29).
(3) Install coupling half (9), new gasket (34), eight nuts (33), eight new lock washers (32), eight flat washers (31),
and eight screws (30) onto tee (29).
(4) Install coupling half (12), new gasket (28), eight nuts (27), eight new lock washers (26), eight flat washers (25),
and eight screws (24) onto tee (29).
(5) Install coupling half (6), new gasket (23), eight nuts (22), eight new lock washers (21), eight flat washers (20),
and eight screws (19) onto wye (18).
(6) Install coupling half (3), new gasket (17), eight nuts (16), eight new lock washers (15), eight flat washers (14),
and eight screws (13) onto wye (18).
(7) Install gasket (11) and quick disconnect cap (10) onto cou pling half (12).
4-66
|