4-17. Adapter, Nozzle.
This task covers:
a. Repair
b. Replace
INITIAL SETUP
Tools:
General Safety Instructions:
None
Materials/Parts:
l
Cleaning Solvent, Item 4, Appendix E
Rags, Wiping, Item 5, Appendix E
l
Equipment Conditions:
FARE shutdown, para 2-12.
WARNING
Do not smoke or use an open flame in the vicin-
ity of the FARE, failure to comply may result in
personnel injury.
Drain any fuel into suitable container. Clean up
any fuel spills to prevent fire or environmental
hazard.
a. Repair.
(1) Inspect nozzle adapter for leaks, ease of operation and missing or damaged components.
WARNING
Cleaning solvent, Federal Specification PD-680, is toxic and flammable. Use only in
a well-ventilated area. Avoid prolonged breathing of fumes. Keep solvent away
from flames. Do not use in excessive amounts. Avoid skin contact.
(2) Clean adapter with cleaning solvent and allow to dry.
(3) Repair is limited to replacement of complete assembly.
b. Replace. (figure 4-10)
(1) Removal.
(a) Slide release sleeve (1) on closed circuit nozzle (2) and remove adapter (3).
(b) Install dust cap (4) on closed circuit refueling nozzle (2), and dust cap (5) on adapter.
(2) Installation.
(a) Remove dust cap (4) from closed circuit refueling nozzle and dust cap (5) from adapter.
(b) Slide release sleeve (1) on closed circuit nozzle (2) and install adapter (3).
4-25
|