TM 10-4930-229-12&P
Table 4-1. Unit Preventive Maintenance Checks and Services (PMCS).
M Monthly
Interval
Equipment is not
Item
Item to be
Ready/Available
No.
M
Inspected
Procedures
If:
1
l
Suction Hose
Check for continuity between coupling
Resistance is greater
ends.
than 5 ohms.
2
Engine
Refer to TM 9-2805-257-14.
3
Pump
Refer to TM 10-4320 -256-14&P.
4
Filter/Separator
Refer to TM 5-4330-217-12&P.
5
Closed Circuit
Refer to TM 5-4930-226-12&P, TM 5-4930-
Refueling Nozzle
234-13&P and TM 5-4930-235-13&P.
6
500 gl Collapsible
Refer to TM 10-8110-201-14&P.
Drum
Section IV. UNIT TROUBLESHOOTING
Paragraph
Page
4-7
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...4-3
4-8
Unit Troubleshooting Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...4-3
4-7. General. This section contains troubleshooting procedures to determine the probable cause of observed
equipment malfunctions. Tests or inspections are provided to isolate the fault component and corrective actions
are provided to eliminate the malfunction.
4-8. Unit Troubleshooting Procedures. Refer to the symptom index to locate the troubleshooting
procedure for the observed malfunction. The table lists the common malfunctions that may occur during the
operation or maintenance of the FARE. Perform the tests or inspections, and the recommended corrective action
in the order listed in the troubleshooting table. If the malfunction is not corrected by the listed corrective actions,
notify your supervisor.
4-3
|