TM 10-4930-229-12&P
Key
Control or Indicator
Function
1
Differential Pressure
Indicates back pressure caused by filter loading.
Indicator
2
Vent Valve
Manually operated to vent air from the filter/separator.
3
Sight Gage
Monitors the amount of collected water in the system.
4
Drain Valve
Provides a way to manually drain collected water from the filter/
separator tank.
2-4. Pump/Engine and Closed Circuit Refueling Nozzles.
a. Pump/Engine. Refer to TM 9-2805-257-14 for the location, purpose and normal settings of the engine
controls.
b. Closed-Circuit Refueling Nozzles. As applicable to the refueling nozzle(s) used with your FARE system,
refer to TM 5-4930-226-12&P (Model CCN101/14), TM 5-4930-234-13&P (Model AE83206R) or TM 5-4930-
235-13&P (Model 125-1000) for the proper attachment, operation and detachment of the nozzle.
Section II. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
Paragraph
Page
2-5
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5
2-6
Purpose of PMCS Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
2-7
Explanation of Columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2-8
Reporting Deficiencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2-9
Special instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
2-10
PMCS Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2-5. General. To insure that the FARE is mission ready, it must be inspected systematically so that defects
may rediscovered and corrected before they result in serious damage or failure. Defects discovered during
operation of the equipment will be noted for future correction. Stop operation immediately if a deficiency is noted
which would damage the equipment or create a hazard if operation were continued. Record all deficiencies and
shortcomings are to be recorded, together with the corrective action taken on DA Form 2404 (Equipment
Inspection and Maintenance Worksheet). Operator PMCS is performed to ensure that the filter/separator is ready
for operation at all times. Perform the checks and services at the following specified intervals.
a. Before you operate, perform your before (B) PMCS. Observe all CAUTIONS and WARNINGS.
b. While you operate, perform your during (D) PMCS. Observe all CAUTIONS and WARNINGS.
c. After you operate, be sure to perform your after (A) PMCS.
d. If your equipment fails to operate, refer to paragraph 3-3.
2-5
|