TM10-4330-235-13&P
Section Ill. Maintenance Procedures
MAINTENANCE OF TANK AND FRAME
5-5. REPAIR TANK AND FRAME
This task covers:
a. Repair
Tools
General Mechanic Tool Kit (Appendix B, Section Ill, Item 4)
Shop Equipment, Welding (Appendix B, Section Ill, Item 5)
Materials/Parts
Dry Cleaning Solvent (Appendix E, Section II, Item 1)
Rags, Wiping (Appendix E, Section II, Item 5)
Equipment Conditions
Filter elements removed (Para. 4-6)
General Safety Instructions
WARNING
Do not smoke within 50 feet (15.34 meters) of filter/separator.
Dry cleaning solvent is potentially dangerous to personnel and
property.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially
dangerous to personnel and property. Avoid repeated and
prolonged skin contact. Do not use near open flame or excessive
heat. Flash point of solvent is 100 - 138 degrees F (38 - 59
degrees C).
When using compressed air, wear safety goggles or glasses and
ensure air blast is not directed at another person. Do not direct
compressed air against the skin.
5-2
|