TM10-4330-235-13&P
c. Connections.
(1)
(2)
(3)
(4)
(5)
NOTE
Make certain that the quick disconnect cams on female coupling
halves are pulled all the way so that male coupling halves can be
securely seated. Check to see that gaskets are installed in each
female coupling half.
Remove dust plug (1) from filter/separator inlet coupling (2) and attach four inch hose (3) with male
coupling to inlet coupling (2). Drive cams home to secure coupling.
Remove dust cap (4) from filter/separator outlet coupling (5).
Make sure that the bevel (6) on the sampling probe (7) is pointed in the direction of female coupling
(8). Remove dust plug (9) from adapter.
Attach adapter (10) to filter/separator outlet coupling (5). Drive cams home to secure coupling.
Remove dust cap (11) from adapter (10) and attach four inch hose (12) with female coupling. Drive
cams home to secure coupling.
2-8
|