Page Title: GROUND CABLE REPAIR
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 10-4320-347-13&P 4.6.  GROUND CABLE REPAIR. This task covers: a. Disassembly c. Assembly b. Repair INITIAL SETUP: Tools Required Tool Kit, General Mechanic's (Appendix B, Item 1) Materials Required None Equipment Condition Pump assembly shut down and cool. Ground cable assembly removed pump assembly (see para.  2.12.). a. Disassembly.  (Refer to Figure 4-3). (1)   Pull protective sleeve (1) down clamp handle (2) until sleeve is away from clamp handle. (2)   Remove wire (3) from clamp (2). (3)   Repeat for other clamp if required. b. Repair.  Repair is limited to replacement of defective parts. c. Assembly. (1)   Strip 1.00 inch of insulation from wire (3) as shown. (2)   Insert stripped portion of wire (3) into crimping area of clamp (2) and crimp clamp handle to secure the wire into the clamp handle. (3)   Repeat for other handle if required. 4-6