TM 10-4320-347-13&P
4.6. GROUND CABLE REPAIR.
This task covers:
a.
Disassembly
c.
Assembly
b.
Repair
INITIAL SETUP:
Tools Required
Tool Kit, General Mechanic's (Appendix B, Item 1)
Materials Required
None
Equipment Condition
Pump assembly shut down and cool.
Ground cable assembly removed pump assembly (see para. 2.12.).
a.
Disassembly. (Refer to Figure 4-3).
(1) Pull protective sleeve (1) down clamp handle (2) until sleeve is away from clamp handle.
(2) Remove wire (3) from clamp (2).
(3) Repeat for other clamp if required.
b.
Repair. Repair is limited to replacement of defective parts.
c.
Assembly.
(1) Strip 1.00 inch of insulation from wire (3) as shown.
(2) Insert stripped portion of wire (3) into crimping area of clamp (2) and crimp clamp handle to
secure the wire into the clamp handle.
(3) Repeat for other handle if required.
4-6
|