TM 10-4320-343-14 To   prevent   rolling   or   sliding,    do  not  work  on  equipment  that  is not   securely   stabilized. Ensure   both   wheels   are   secure. Failure   to   obey   this   warning   may   result   in   serious   personal i n j u r y. If   oil   level   cannot   be   determined,   notify   supervisor. a. Look   into   sight   gauge   (figure   3-4,   1)   to   verify   oil   level. b. I f    o i l    l e v e l    i s    l o w,    remove   vent   cap   (2)   and   fill   to   proper   level   in accordance   with   LO   10-4320-343-12. c . Install   vent   cap   (2). 3-11 NOTE