TM 10-4320-343-14
WARNING
To prevent rolling or sliding, do not work on equipment that is not securely
stabilized. Ensure both wheels are secure. Failure to obey this warning may result
in serious personnel injury.
CAUTION
Do allow water separator to remain undrained after operation of equipment.
Failure to obey this caution could result in equipment damage.
a.
Place suitable container under water separator (1, Figure 3-3 or 3-3.1).
NOTE
Water separator on Model 350 PAFN may require priming after draining water.
Refer to paragraph 5.2.1 priming procedures.
b.
On Model 350 PAFN, open drain valve (2, Figure 3-3.1) and drain water separator until clean fuel is observed. When
clean fuel is observed, close drain valve.
c.
On other models, remove plug (2, Figure 3-3) or open petcock drain valve and drain water until clean fuel is observed.
When clean fuel is observed, install plug (2) or close petclock drain valve.
Figure 3-3.1 Filter Separator Servicing (Model 350 PAFN).
Change 1 3-9
|