TM 10-4320-343-14
4.15.3.1 Removal.
WARNING
To prevent rolling or sliding, do not work on equipment that is not securely
stabilized. Ensure both wheels are secure. Failure to obey this warning may result
in serious personnel injury.
a.
Disconnect hoses(Figure 4-62, 1).
b.
Remove eight nuts(2) and lockwashers(3) from studs(4) of centrifugal pump.
c.
Remove suction manifold(5) from centrifugal pump.
d.
Remove and discard gasket(6).
e.
Remove fitting (s)(7) from suction manifold. (All models except Model 350 PAFN),
f.
Remove elbow(8), tee(9) and bushing(10) from suction manifold. (Model 350 PAFN only).
4.15.3.2. Installation.
a.
Wrap bushing(10), tee(9) and elbow(8) with antisezing tape then install on suction manifold.(Model 350 PAFN
only).
b.
Wrap fitting(s)(7) with antisezing tape then install on suction manifold. (All models except Model 350 PAFN).
c.
.Install gasket(6) over studs(4) of centrifugal pump.
d.
Install eight lockwashers(3) and nuts(2).
e.
Connect suction hoses(1) to fittings.
4-118 Change 1
|