TM 10-4320-343-14
Figure 4-57.
Control Box Maintenance.
4.14.4.2 Removal.
a.
Disconnect electrical connector (1, figure 4-57).
b .
Remove four screws (2) and lockwashers (3).
c .
Carefully lift control box (4) straight up off of actuator (5).
4.14.4.3 Installation.
a .
Place control box (4) on actuator (5) and install with four lockwashers (3)
and screws (2).
b.
Connect electrical connector (1).
c .
Adjust control box (paragraph 4.14.4.1).
4-107
|