TM 10-4320-343-14
4.13.9 Run Relay (K2) Replacement (Non-regulated pump only).
This task covers:
4.13.9.1 Removal
4 .
1
3 .
9 .2
I n s t a l l a t i on
INITIAL SETUP
Tools
Equipment Conditions
General Mechanics Tool Kit (appendix B,
Equipment shut down,
Section III, Item 1)
paragraph 2.5.1.2 or
(continued)
r e f e r to
2 .
5 .
2 .
2.
Materials/Parts
General Safety
Instructions
Tags (appendix E, Section II, Item 12)
To prevent rolling or sliding, do not
work on equipment that is not securelyk
Equipment Conditions
s t a b i l i z e d .
Equipment shut down, refer to
DO not work on equipment without
paragraph 2.5.1.2 or 2.5.2.2.
following standard shop safety
precautions.
Figure 4-49.
4.13.9.1 Removal.
To prevent rolling or
s e c u r e l y s t a b i l i z e d.
warning may result in
Relay K2 Removal and Installation.
sliding, do not work on equipment that is not
Ensure both wheels are secure.
Failure to obey this
serious personal injury.
a .
Tag and disconnect wires
(figure 4-49, 1) from relay (2).
b .
Remove two screws (3) and nuts (4) from front of control panel assembly-
C.
Remove relay (2) from control panel.
4.13.9.2 Installation.
a .
Position relay (2) in place on back of control panel assembly.
b.
Install two nuts (4) and screws (3) into relay (2) through front of control
panel.
c .
Connect wires (1) to relay (2) and remove tags.
4-92
|