TM 10-4320-343-14
4.13.6 Suction Gauge (M4) and Discharge Gauge (M5) Replacement.
This task covers:
4.13.6.1 Removal
4 .
13 . 6 . 2 I n s t a l l a t i on
INITIAL SETUP
Tools
General Mechanics Tool Kit (appendix B,
Section III, Item 1)
Materials/Parts
Tags (appendix E, Section II, Item 12)
Equipment Conditions
Equipment shut down, refer to
paragraph 2.5.1.2 or 2.5.2.2.
Equipment Conditions (continued)
Control Panel Assembly Cover removed,
paragraph 4.13.1.
General Safety Instructions
To prevent rolling or sliding, do not
work on equipment that is not securely
s t a b i l i z e d .
DO not work on equipment without
following standard shop safety
precautions.
Figure 4-46.
Suction Gauge (M4) and Discharge Gauge (M5) Replacement.
4.13.6.1 Removal.
To prevent rolling or sliding, do not work on equipment that is not
s e c u r e l y s t a b i l i z e d.
Ensure both wheels are secure.
Failure to obey this
warning may result in serious personal injury.
and disconnect hose (figure 4-46, 1) from gauge (2).
a .
Tag
b .
Remove three nuts (3), lockwashers (4), and screws (5) from gauge (2) .
c .
Remove gauge (2) from front of control panel.
4.13.6.2 Installation.
a .
Install gauge (2) through front of control panel.
b .
Install three screws (5), lockwashers (4), and nuts (3) on gauge (2).
c .
If snubber is installed between hose and gauge, remove and discard snubber,
adapter,
and elbow.
d.
Connect hoses (1) to gauge (2) and remove tags.
4-89
|