Page Title: Control Panel Test. (Model 350 PAFN only)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 10-4320-343-14 4.13.2.1 Control Panel Test.  (Model 350 PAFN only) INITIAL SETUP Tools Equipment Conditions General Mechanic's Tool Kit, (appendix B Equipment shut down, refer to Section III, Item 1) paragraph 2.5.2.2. Test Equipment Multimeter, (appendix B, Section III, Item 2) General Safety Instructions To prevent rolling or sliding, do not work on equipment Materials/Parts that is not securely stabilized. Tags (appendix E, Section II, Item 12) Do not work on equipment without following standard shop safety precautions. Test. WARNING Do not work on wiring harness with negative battery terminal connected. To   prevent   rolling   or   sliding,   do   not   work   on   equipment   that   is   not   securely stabilized.  Ensure both wheels are secure. Failure to obey these warning may result in serious personal injury. NOTE All electrical checks, should be done with both battery cables disconnected. For testing of other components (pressure gauges, ammeter, hourmeter/tachometer) system must be operating. a. Check wiring harness assembly for continuity or short(Figure 4-42.1).  If defective  refer to paragraph 4.12.4.1. b. Switch S1. (1) Close switch (pulled out) and check for continuity between contacts 1/4 and 2/3. (1) Open switch (pushed in) and check for open circuit between contacts 1/4 and 2/3. c. Switch S2. (1) Close switch  (pressed in) and check for continuity between contacts 1/2. (2) Open switch (released) and check for open circuit between contacts 1/2. d. Switch S3. (1) Close switch (pressed in) and check for continuity between contacts 1/2. (2) Open switch (released) and check for open circuit between its contacts 1/2. e. Relay K1. (1)  Apply  positive12  V  dc  to  contact  2  and  a  ground  to  contact  7  and  meassure  for  continuity  between  contacts 1/3 and 6/8. 4-82.2  Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business