4.12.2.1 Removal.
To prevent rolling or sliding, do not work on equipment that is not
s e c u r e l y s t a b i l i z e d .
Ensure both wheels are secure.
Do not work on battery with negative terminal connected.
Failure to obey these warnings may result in serious personal injury.
a .
Loosen nuts (figure 4-37, 1 and 2) and remove negative battery
terminals (3 and 4) from posts (5 and 6).
b .
Loosen nuts (7 and 8) and remove positive battery terminals (9 and 10) from
posts (11 and 12).
c .
Remove batteries (13 and 14).
4.12.2.2 Servicing.
Clean terminals (3, 4, 9 and 10) and posts (5, 6, 11, and 12) with standard
battery cable and post cleaning brush.
4.12.2.3 Installation.
a .
Install batteries (13 and 14).
b .
Install positive battery terminals (10 and 9) and tighten nuts (8 and 7).
c .
Install negative battery terminals (4 and 3) and tighten nuts (2 and 1).
d .
Coat battery terminals (10, 9, 4, and 3) with a light coat of grease.