Do not use dry cleaning solvent without proper ventilation and clothing.
DO not smoke or use near open flame or excessive heat.
Dry cleaning
solvent is potentially dangerous to personnel and property.
Clean parts
in a well-ventilated area.
Avoid inhalation of solvent fumes.
Wear
goggles and rubber gloves to protect eyes and skin.
Wash exposed skin
thoroughly.
Flash point of solvent is 100°F to 138°F (38°C to 59°C).
Failure to obey this warning may result in personal injury or death.
Clean all parts of spark arrestor with wire brush and solvent.
Inspect baffles (8) for cracks, holes or other damage.
Check base (9) for cracks and holes.
Position mounting stud (10) in base (9).
Align indentations of baffles (8) and position to base (9) as indicated in
figure 4-2.
Install cap (7), washer (6) and thread nut (5) on to mounting stud (10).
Tighten nut.
4.9.1.3 Installation.
a.
Place spark arrestor (4) on exhaust pipe (3).
b.
Position clamp (2) so that it tightens on both spark arrestor (4) and exhaust
pipe (3).
c .
Tighten nuts (1).