TM 10-4320-343-14 Table 4-2.1.  Unit Troubleshooting Table (Model 350 PAFN).  (Continued) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1.  ENGINE WILL NOT CRANK (CONTINUED). Step 4 Test battery (paragraph 4.12.1). a.  Recharge battery if charge is low, but battery is otherwise good. b.  Replace battery (paragraph 4.12.2) if it fails to hold a charge. Step 5 Test system wiring (paragraph 4.12.4.1). Replace    system    wiring    harness    (paragraph    4.12.5.1)    or    replace    individual    defective    wires    as appropriate. Step 6 Test control panel (paragraph 4.13.2.1). Repair control panel (paragraph 4.13.3 through 4.13.10) as required. Step 7 Test V-belt contact switch (paragraph 4.10.9) Replace V-belt contact switch (paragraph 4.10.10) if defective. Step 8 Test wiring harness (item 9, Figure 4-52) for continuity and shorts. a.  Replace wiring harness (paragraph 4.14.1) if defective. b.  If wiring harness is not defective, replace pressure controller (paragraph 4.14.2). Step 9 Check for 12 Vdc at bottom terminal of starter solenoid (Figure 4-17) to ground while attempting to start engine. Replace starter (paragraph 4.10.13) if no voltage. Step 10 Remove   V-belt   guard   (paragraph   4.10.6)   and   attempt   to   rotate   engine   crankshaft   by   hand   at   the crankshaft pulley. Replace starter (paragraph 4.10.13) if crankshaft can be turned by hand. Step 11 Notify Direct Support Maintenance. 2.  ENGINE WILL NOT START. WARNING Do not smoke or use spark or flame producing equipment while troubleshooting. Move   equipment   off   line   and   have   a   fire   extinguisher   at   hand   when   troubleshooting involves electrical circuits. Failure to heed these warnings may result in death or serious injury of personnel. 4-10.2  Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business