TM 10-4320-342-24
3-40.
AIR CLEANER MOUNTING BAR ASSEMBLY REPAIR.
This task covers:
a. Disassembly
b. Repair
c. Assembly
INITIAL SETUP
Tools
Equipment Condition
Blind Riveter (App B, Sect III, Item 2)
Air Cleaner Mounting Bar Assembly removed
Drill (App B, Sect III, Item 2)
(Para 2-93)
Set, Drill Twist (App B, Sect III, Item 2)
a. DISASSEMBLY. Refer to Figure 3-63.
(1)
As required, remove rivets (1) and turnlock receptacles (2) from air cleaning mounting bar (3).
(2)
As required, remove blind rivnuts (4) from air cleaner mounting bar (3).
b. REPAIR.
Repair consists of replacing damaged and/or missing components.
c. ASSEMBLY.
(1)
If removed, install rivets (1) and turnlock receptacles (2) on air cleaner mounting bar (3).
(2)
If removed, install blind rivnuts (4) on air cleaner mounting bar (3).
Figure 3-63. Air Cleaner Mounting Bar Assembly Repair
3-129
|