TM 10-4320-342-24
3-34.
WINCH CONTROL CABLE ASSEMBLIES REPAIR
This task covers:
a. Removal
b. Repair
c. Installation
INITIAL SETUP
Tools
Equipment Condition
General Mechanics Tool Kit (App B, Sect III,
Battery disconnected (Para 2-62)
Item 1)
200/600 GPM Pump Assembly removed from
Wire Stripper (App B, Sect III, Item 3)
system (Para 2-9, TM 10-4320-342-10)
Solder Gun (App B, Sect III, Item 3)
Heat Gun (App B, Sect III, Item 3)
Reference
Electric Power Generation in the Field
Materials/Parts
(FM 20-31)
Solder (App E, Item 24)
Tags (App E, Item 16)
a. REMOVAL. Refer to Figure 3-56.
(1)
Open door panel (1).
(2)
Disconnect electrical connectors (2 and 3) from receptacles (4 and 5).
(3)
Remove screws (6) and cover (7) from junction box (8).
NOTE
Installing tags on wire connections will help during installation of cables.
(4)
Tag electrical leads (9, 10, 11 and 12).
(5)
Remove screw (13) and electrical lead (9) from terminal board (14).
(6)
Remove nuts (15), lockwashers (16) and electrical leads (10, 11 and 12) from solenoid valves (17, 18 and 19).
(7)
Unscrew seal nut (20) and remove cable (21) from adapter (22) on junction box (8).
(8)
Remove seal (23), seal ring (24) and seal nut (20) from cable (21).
(9)
Unscrew seal nut (25) and remove cable (26) from adapter (27) on junction box (8).
(10)
Remove seal (28), seal ring (29) and seal nut (25) from cable (26).
b. REPAIR.
Refer to Appendix D, Item 15 and FM 20-31, Electric Power Generation in the Field to manufacture/repair
the winch control cable assemblies.
3-120
|