3-30.
CONTROL BOX WIRING HARNESS REPAIR - continued.
Refer to Figure 3-53.
NOTES
· Heat shrinks should be positioned one inch from wire end to avoid burning
during soldering.
· Wire leads without terminals should be stripped .250 inch and tinned.
(1)
Position heat shrinks (26) on wire leads (27).
(2)
Strip and tin end of wire leads (27).
(3)
Install and solder end of wire leads (27) on indicator lights (28).
(4)
Slide heat shrinks (26) over soldered connections on indicator lights (28) and shrink.
(5)
Position heat shrinks (23) on wire leads (24).
(6)
Strip and tin end of wire leads (24).
(7)
Install and solder end of wire leads (24) on variable resistor (25).
(8)
Slide heat shrinks (23) over soldered connections on variable resistor (25) and shrink.
(9)
Install wire leads (21), flat washers (20) and nuts (19) on ammeter (22).
(10)
Install wire leads (17), lockwashers (16) and screws (15) on circuit breakers (18).
(11)
Install wire leads (13), lockwashers (12) and screws (11) on master switch (14).
(12)
Install wire leads (9) and screws (8) on panel lights (10).
(13)
Install wire leads (6), lockwashers (5) and screws (4) on toggle switches (7).
(14)
Remove tags from wiring harness (3).
(15)
Close and secure control panel (2).
(16)
Close and secure cover (1).