TM 10-4320-342-24
3-30. CONTROL BOX WIRING HARNESS REPAIR - continued
Refer to Figure 3-51.
(11)
Disconnect electrical connector (1) from voltage regulator (2).
(12)
Remove nuts (3), lockwashers (4) and wire leads (5) from K3 relay (6).
(13)
Remove locknuts (7), flat washers (8) and wire leads from K2 and K6 relays (10).
(14)
Remove nuts (11), flat washers (12) and wire leads (13) from R4 shunt (14).
(15)
Remove screws (15), lockwashers (16) and wire leads (17) from R4 shunt (14).
(16)
Remove locknuts (18), flat washers (19), fuse link (20) and wire leads (21) from fuse holder (22).
(17)
Remove screws (23) and wire leads (24) from terminal boards (25).
(18)
Remove self-locking nuts (26), flat washers (27) and relays (28, 29, 30, 31 and 32) from studs (33) on mounting
bracket (34).
(19)
Remove nuts (35), flat washers (36), screws (37) and mounting bracket (34).
(20)
Tag and disconnect wiring from back of relay sockets (40, 41, 42, 43 and 44).
(21)
Remove self-locking nuts (38) and flat washers (39) from studs (33).
(22)
Remove relay sockets (40, 41, 42, 43 and 44) from mounting bracket (34).
(23)
Disconnect electrical connectors (45, 46, 47 and 48) from electrical connectors (49, 50, 51 and 52).
(24)
Remove wiring harness (53) from control box (54).
b. REPAIR.
Refer to FM 20-31 for repair of control box wiring harness.
3-109
|