TM 10-4320-342-24
2-88.
RECEPTACLE CONNECTOR (SLAVE) REPLACEMENT]
This Task Covers
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Condition
General Mechanics Tool Kit (App B, Sect III,
Battery disconnected (Para 2-61)
Item 1)
Materials/Parts
Tags (App E, Item 16)
Self-locking Nut (App F, Item 63)
a. REMOVAL. Refer to Figure 2-118.
(1)
Open doors (1 and 2).
(2)
Tag electrical wiring (3).
(3)
Remove bolts (4), lockwashers (5) and wiring (3) from receptacle connector (6).
(4)
Remove self-locking nuts (7), flatwashers (8), bolts (9), packing plate (10), gasket (11) and receptacle connector
(6) from frame (12).
b.
INSTALLATION,
(1)
Install gasket (11) on receptacle connector (6) and position receptacle connector (6) in frame (12).
(2)
Align terminal ring (13), receptacle connector (6), gasket (11) and backing plate (10) on frame (12) and install
bolts (9).
(3)
Install flatwashers (8) and self-locking nuts (7) on bolts (9).
NOTE
Wire numbers are stamped on each electrical wire. This information, in
conjunction with data on FO-1 and FO-2, 200/600 GPM Pump Wiring Diagram, may
be used to connect wires if tags are lost or illegible.
(4)
Position electrical wiring (3) as tagged during removing and install lockwashers (5) and bolts (4).
(5)
Close doors (1 and 2
2-266
|