TM 10-4320-342-24
2-81. WINCH CONTROL BOX ASSEMBLY REPAIR continued.
c.
REPAIR.
Repair is limited to the replacement of damaged components.
d.
ASSEMBLE. Refer to Figure 2-111.
(1)
Install adapter (23) in junction box (3).
(2)
Slide seal nut (19), seal ring (22) and seal (21) and cable (20).
(3)
Install cable (20) in adapter (23).
(4)
Install terminal board (17) and secure with screws (18) in junction box (3).
(5)
Position solenoid valves (8) in junction box (3) and secure with screws (14) and flatwashers (15).
NOTE
Wire numbers are stamped on each electrical wire. This information, in
conjunction with data on FO-1 and FO-2, 200/600 GPM Pump Wiring Diagram, may
be used to connect wires if tags are lost or illegible.
(6)
Install connectors (9, 10, 11, 12 and 13), electrical leads (4 and 5), lockwashers (7) and nuts (6) on solenoid
valves (8) as tagged.
(7)
Slide seal nut (19), seal ring (22) and seal (21) down cable (20).
(8)
Position seal (21) in adapter (23) and tighten seal nut (19).
(9)
Install cover (2) and screws (1) on junction box (3).
Refer to Figure 2-110.
(10)
Install adapter (15) in box (4).
(11)
Slide seal nut (11), seal ring (14) and seal (13) on cable (12).
(12)
Install cable (12) in adapter (15) on box (4).
(13)
Install electrical leads (6) on switches (10).
(14)
Install electrical lead (5), screw (7) and lockwasher (8) on box (4).
(15)
Install seal (13) in adapter (15) and tighten seal nut (11) on adapter.
(16)
Install cover (3), flatwashers (2) and screws (1) on box (4).
2-254
|