TM 10-4320-342-24 2-79.  RELAYS (K1, K4, K5, K7 and K11) REPLACEMENT (TYPICAL). This task covers: a.  Removal b.  Installation INITIAL SETUP Tools Tools General Mechanics Tool Kit (App B, 200/600 GPM Pump shutdown Sect III, Item 1) (Para 2-7c, TM 10-4320-342-10) NOTE This  procedure  covers  the  replacement  of  relay  K1.    Replacement  of  K4,  KS,  K7 and K11 relays are identical to K4 relay. a. REMOVAL.  Refer to Figure 2-106. (1)   Open and lock control panel door (1) in place with door latch (2). (2)   Open control panel (3). (3)   Remove nut (4) and washer (5) from stud (6). (4)   Remove relay (7) from plug (8). b. INSTALLATION. (1)   Install relay (7) in plug (8). (2)   Install washer (5) and nut (4) on stud (6). (3)   Close control panel (3). (4)   Unlatch door latch (2) and close control panel (1). 2-246