TM 10-4320-342-24
2-75. SHUNT R4 REPLACEMENT
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Condition
General Mechanics Tool Kit (App B, Sect III,
200/600 GPM Pump shut down (Para 2-7c,
Item 1)
TM 10-4320-320-10)
Materials/Parts
Tags (App E, Item 16)
Locknut (App F, Item 63)
a.
REMOVAL. Refer to Figure 2-102.
(1) Open cover (1) and lock in place.
(2) Open control panel (2).
(3) Tag electrical wires (3 and 4)
(4) Remove nuts (5), flatwashers (6) and wires (3) from shunt (7).
(5) Remove screws (8), lockwasher (9) and wire (4) from shunt (7).
(6) Remove locknuts (10), flatwashers (11), screws (12) and shunt (7) from control box (13).
b.
INSTALLATION.
(1) Position shunt (7) in control box (13) and secure with screws (12), flatwashers (11) and locknuts (10).
(2) Install screws (8), lockwashers (9) and wire (4) onto shunt (7) as tagged during removal.
(3) Install nuts (5), flatwashers (6) and wire (3) onto shunt (7) as tagged during removal.
(4) Close control panel (2) and cover (1).
2-238
|