TM 10-4320-342-24
2-68. AMMETER (BATTERY) REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Condition
General Mechanics Tool Kit (App B, Sect III,
Battery disconnected (Para 2-61)
Item 1)
Material/Parts
Tags (App E, Item 16)
a. REMOVAL. Refer to Figure 2-95.
(1)
Open cover (1) and lock in place.
(2)
Open control panel (2).
(3)
Tag electrical wires (3).
(4)
Remove nuts (4), two flatwashers (5) and electrical wires (3) from ammeter (6).
(5)
Remove nuts (7), lockwashers (8), screws (9) and ammeter (6).
b. INSTALLATION.
(1)
Position ammeter (6) in cutout on control panel (2).
(2)
Secure with screws (9), lockwasher (8) and nuts (7).
NOTE
Wire numbers are stamped on each electrical wire. This information, in
conjunction with data on FO-1 and FO-2, 200/600 GPM Pump Wiring Diagram, may
be used to connect wires if tags are lost or illegible.
(3)
Install two flatwashers (5), electrical wiring (3) and nuts (4) to ammeter (6).
(4)
Close control panel (2).
(5)
Unlock and close cover (1).
2-224
|