TM 10-4320-342-24
2-46. ELECTRONIC SEQUENCE UNIT (ESU) REPLACEMENT.
This Task Covers
a. Removal
b. Installation
INITIAL SETUP
This Task Covers
Tools
Equipment Condition
General Mechanics Tool Kit (App B, Sect III,
200/600 GPM Pump shut down (Para 2-7c,
Item 1)
TM 10-4320-342-10)
a. REMOVAL. Refer to Figure 2-73.
(1)
Open door (1).
(2)
Disconnect electrical connectors (2 and 3) from ESU (4).
(3)
Support ESU (4) and remove bolts (5), flatwashers (6) and ESU (4) from bracket (7).
b. INSTALLATION.
(1)
Position ESU (4) on bracket (7) and install bolts (5) and flatwashers (6).
(2)
Connect cable connectors (2 and 3) to ESU (4).
(3)
Close panel (1).
2-174
|