TM 10-4320-342-24
2-38. FUEL DRAIN CHECK VALVE REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Condition
General Mechanics Tool Kit (App B, Sect III,
200/600 GPM pump assembly removed from
Item 1)
system (Para 2-9, TM 10-4320-342-10)
Material/Parts
General Safety Instructions
Antiseize Tape (App E, Item 6)
WARNING
Fuels and fuel vapors are toxic and flammable. Be
Careful when working around fuel so not to come in
contact. Fuel can cause injury to personnel. For
disposal of contaminated fuel, refer to FM 10-20.
a. REMOVAL. Refer to Figure 2-63.
(1)
Open door (1).
(2)
Disconnect tubes (2 and 3).
NOTE
Note position of adaptor and elbow in relation to flow arrow on check valve.
(3)
Remove adapter (4) and elbow (5) from check valve (6).
b. INSTALLATION.
NOTE
Install antiseizing tape (teflon tape) on all male threads and wrap tape in direction
of threads. Do not allow teflon tape to extend beyond end of threads.
(1)
Install adapter (4) and elbow (5) in check valve (6) as noted during removal.
(2)
Position check valve (6) and connect tubes (2 and 3).
(3)
Close door (1).
2-151
|