TM 10-4320-342-24
2-15. DRAIN TANK AND TUBES REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
General Safety Instructions
General Mechanics Tool Kit (App B, Sect III,
WARNING
Item 1)
Fuels are toxic and flammable. Avoid contact
with skin, eyes and clothes and don't breathe
Material/Parts
vapors. Do not use near open flame or excessive
Tape, Antiseize (App E, Sect II, Item 6)
heat. Death or serious injury to personnel may
result.
Equipment Condition
200/600 GPM pump removed from system
(Para 2-9, TM 10-4320-342-10)
a.
REMOVAL. Refer to Figure 2-35.
(1)
Disconnect and remove tubes (1, 2 and 3).
(2)
Remove bolts (4), flatwashers (5) and drain tank (6).
NOTE
Note position of valve, elbows and tee prior to removal.
(3)
Remove elbow (7) from drain tank (6).
(4)
Remove tee (8) from elbow (9).
(5)
Remove elbow (9) from valve (10).
(6)
Remove valve (10) from swivel adapter (11).
(7)
Remove swivel adaptor (11) from drain tank (6).
b.
INSTALLATION.
NOTE
Install antiseizing tape (teflon tape) on all male pipe threads and wrap tape in
direction of threads. Do not allow tape to extend beyond end of threads.
(1)
Install swivel adapter (11) into valve (10).
2-98
|