2-9. PREPARATION FOR MOVEMENT.
a.
The following prepares the 200/600 GPM Pump for movement. Refer to Figure 2-10.
(1)
Shutdown 200/600 GPM Pump. Refer to paragraph 2-7 shutdown.
(2)
Disconnect external fuel supply. Refer to applicable system TM.
(3)
Disconnect 200/600 GPM fuel pump hoses. Refer to applicable system TM.
(4)
Remove ground rod. Refer to applicable systems TM.
(5)
On the control panel door (1). Remove door latch(2) from mounting lug (3).
(6)
Close control panel door (1) and lock two turn-lock fasteners (4).
WARNING
To avoid burns, wear hand protection when removing muffler extension. The
muffler extension may be very hot.
(7)
Insert handles (5) in exhaust extension (6).
WARNING
Lifting or moving equipment incorrectly may cause serious injury. Do not try to lift
or move more than 50 pounds by yourself. Get an assistant. Do not support
weight with your back.
(8)
On exhaust extension (6) release ten turn-lock fasteners (7) and remove exhaust extension(6) from muffler (8).
(9)
On door (9) release 15 turn-lock fasteners (10) and open door.
(10) Install handle (5) in mounting brackets (11) and slide exhaust extension (6) inward on 200/600 GPM Pump (8).
(11) Close door (9)and lock 15 turn-lock fasteners (10).
(12) Install panel (12) on muffler (8) and lock ten turn-lock fasteners (13).
2-46
|