TM 10-4320-342-10
2-7. OPERATING PROCEDURES - continued.
b.
Operate. Refer to Figure 2-8.
NOTE
Engine reaches operating speed in one minute on the 200/600 GPM Pump and is
ready for operation.
(1)
Set PUMP CLUTCH switch (10) to engaged.
(2)
When DISCHARGE pressure gage (15) reads 20 psi, turn PRIMING SHUT OFF VALVE (1) handle to off.
(3)
FUEL SELECTOR VALVE (4) turn handle to internal.
(4)
On priming vent drain tank handle (8), set handle to open (horizontal position) for one minute then close
(vertical position).
c.
Shutdown. Refer to Figure 2-8.
(1)
On the control panel (9) set PUMP CLUTCH switch (10) to disengaged.
(2)
START switch (11) set to stop.
CAUTION
Do not turn engine pumps off until engine stops rotating (approximately one
minute). Damage to turbine could occur.
(3)
ENGINE PUMPS switch (12) set to off when engine stops rotating.
(4)
Push MASTER switch (14) off.
(5)
FUEL SELECTOR VALVE (4) turn handle to off.
(6)
Loosen T-handle (6) and rotate handle (7) to closed position (horizontal position). Tighten T-handle (6).
(7)
Disconnect battery (1) and pull out circuit breakers (2).
2-43
|