TM 10-4320-324-14
3-6. Service Batteries.
CAUTION
To prevent short circuits, never rest tools on battery.
a.
Servicing Battery. Prior to operating the unit, check
electrolyte level in each cell as follows:
(1)
Remove two wing nuts (1), two washers (2),
strap (3), and two covers (4).
(2)
Remove caps (5).
WARNING
To prevent serious burns, take the necessary
precautions when filling battery with electrolyte.
Do not allow electrolyte to come in contact with
skin or eyes. Use rubber gloves and protective
clothing.
(3)
Visually check the electrolyte level of all cells.
(4)
Electrolyte level must cover lead plates (6) and
be to a level at the lower portion of the fill hole.
(5)
If electrolyte level is low, add water only.
(6)
Replace caps (5).
(7)
Install covers (4) and strap (3) with washers (2) and wings nuts (1).
3-11
|