TM10-4320-324-14
5-28. Frame Assembly Repair/Replacement.
This task covers:
a.
Cleaning/lnspection
b.
Repair
c.
Follow-on Maintenance
INITIAL SETUP:
Tools
NOTE
Tool kit, general mechanics, item 35, section III,
Only remove panels and components in the area
appendix B
which requires repair.
References
General Safety Instructions
TM 9-237
Wear personal protective equipment
when using cleaning solvent.
Equipment Condition
Pump removed (para 5-23).
Axle removed (para 5-27).
Fuel tank removed (para 5-11).
a.
Cleaning/Inspection.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapor. Do not use
near open flame or excessive heat. The flash point is 1000F-1380F (380-500C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
(1)
Clean frame and braces with cloth and dry cleaning solvent P-D-680. Dry thoroughly.
(2)
Inspect all welds for cracks.
5-98
|