TM 10-4320-324-14
5-23. Pump Assembly Replacement (CONT).
(4)
Remove two self locking nuts (6), two bevel washers (7), two flat washers (8), and two screws (9).
(5)
With weight of pump (5) on lifting device, slowly and carefully pull pump assembly straight up from
frame and place on an adequate and clean stand.
(6)
Remove two spacers (10) from frame.
b.
Installation.
(1)
Aline two spacers (10) on pump mounting holes in frame.
(2)
Lift pump (5) and position on frame.
(3)
Install two screws (9), two flat washers (8), two bevel washers (7), and two self locking nuts (6).
5-76
|