TM 10-4320-324-14
d.
Cleaning, Inspection, and Repair.
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only in
a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapor. Do not use near
open flame or excessive heat. The flash point is 100°F-138°F (38°-50°C). If you become dizzy while
using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made, wash
your eyes with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 psi. Use only with effective chip guarding
and personal protective equipment (goggles/shield, gloves, etc).
(1)
Wash all parts in clean dry cleaning solvent P-D-680 and blow out with compressed air.
e.
Assembly.
(1)
Install shims (7) and spring (6) in holder (8) and plunger (5) with shoulder next to spring.
(2)
Insert intermediate piece (4) with guide pins into holes in holder. Insert needle (3) in nozzle (2). Aline
body holes with guide pins in intermediate piece (4) and insert guide pins, then install union nut (1).
(3)
Test injection nozzle in accordance paragraph b.
5-41
|